This class b amplifier is designed for commercial and industrial public address applications. Rack mount design in 2U type and rated power is 350W /450W/650W.
Both balanced and unbalanced line inputs are available for each channel. Balanced line output feeds to another power amplifier as well as secures the signal transmission is less noise and longer distance. 70V, 100V and 4-16ohm speaker outputs are convenient for installation when selection different speaker matching. A master volume control is included. Complete protection includes clip, short circuit, high temp and overload. With indications for power, signal, clip, protection and temp. This product ispowered mixer amp.


|
Model |
MP1500 |
|
Rated power |
350W |
|
Rated output voltage |
70V/100V/4-16 ohm |
|
Inputsensitivity |
0dBu |
|
S/N Ratio |
> 80dB |
|
Damping Factor |
200:1 |
|
Input CMRR |
Greater than 90dB |
|
THD into 4W/1kHz |
<0.3% |
|
Frequency response |
50Hz ~15kHz (±3dB) |
|
Slew Rate |
>15V/microsecond |
|
Power Consumption |
700W |
|
Powerrequirement |
AC220~240V/50~60Hz |
|
Unit Size (mm) |
(L×W×H)483´380x88 |
|
Netweight |
14.5Kg |
MP3000 1000W-2000W Classical Series Power AmplifierNovember 15, 2016Description:This class b amplifier is designed for commercial and industrial public address applications. Rack mount design in 2U type and rated power is 1000W/1500W/2000W.Both balanced and unbalanced...view
MG10 10 Channel Audio MixerDecember 21, 2017MG series has intuitive, easy to use interface, including from 6 channels to 20 channels in a variety of models, suitable for a variety of users and usages. The firm structure and flexible design make...viewwe will contact you within 24 hours.
DSPPA | Holiday Notice for China's National Day & Mid-Autumn FestivalSeptember 28, 2025Abstract: May you enjoy joyful gatherings and happiness during the double festivals, with continued success in all your endeavors.view
Power Requirements to Pay Attention to when Using the Conference SystemSeptember 28, 2022When using the conference system, you need to pay attention to the following power requirements:1. When using the mobile equipment of the conference system in the conference room, special power socket...view