EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating status and recording of operating logs. It meets the relevant standard of “EN54-16 Voice Alarm Control and Indicating Equipment”. The broadcasting system can be used for fire emergency broadcasting, daily service broadcasting and background broadcasting; this system is positioned as a small emergency broadcasting system, mainly used in small shopping malls, small office buildings and exhibition halls, etc.
PAVA9425E is a 4-zone expansion amplifier with main/backup switching function in the EN54-16 system, and is designed to be 2U high, with 2 microphone inputs, 4 analog inputs and 1 line output; features a backup amplifier module; supports the total power of up to 1000W; holds 4 zone outputs, with the total power of 1000W for all zones.



Model | PAVA9425E | ||
Rated Output Power | ≥1000W (100V) | ||
Input Sensitivity | EMC MIC | —— —— | |
MIC | 5±0.5mV 10kΩ | ||
LINE | 1000±100mV 10kΩ | ||
Harmonic Distortion | EMC MIC | <1% 1kHz | |
MIC | 1%1khz | ||
LINE | <1% 1kHz | ||
Frequency Response | EMC MIC | 80Hz-15kHz (±3dB) | |
MIC | 1%1khz | ||
LINE | 50Hz-18kHz (±3dB) | ||
S/N Ratio | EMC MIC | >75dB (A weighted) | |
MIC | 1%1khz | ||
LINE | >80dB (A weighted) | ||
EMC LINE AUX OUT | Output Voltage | 1000mV | |
Frequency Range | 80Hz-15kHz(±3dB) | ||
Harmonic Distortion | <1% 1kHz | ||
System Connection Control Contact Output/Input | System Fault Relay Output | Short circuit, no voltage | |
Emergency Mode Relay Output | Short circuit, no voltage | ||
Fire Reset Input | Short circuit, t≥0.5S, no voltage | ||
4-Channel Dry Contact Output | Short circuit, no voltage | ||
4-Channel Dry Contact Input | Short Circuit Mode | Short circuit input, no voltage | |
Level Mode | 3.3V~24V | ||
Working Power | AC | AC220V-240V/50-60Hz | |
DC | DC 24V/34A | ||
Package Dimensions (L*W*H) | 625×635×165mm | ||
Machine Dimensions (L*W*H) | 483*430*88mm | ||
Gross Weight | 14kg | ||
Net Weight | 12.05kg | ||
PAVA9500 8 Zones Voice Alarm Fire Evacuation System Host with Main/Backup SwitchingJune 27, 2023EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating stat...view
PAVA9003 Power Management UnitMarch 5, 2026The PAVA9003 Power Management Unit is designed for use with EN54-16 systems. It provides backup power supply for the PAVA9500 amplifier host, PAVA9500E expansion amplifier, and PAVA9425E expansion amp...view
PAVA9008 16 Zones Remote Paging MicrophoneJune 27, 2023EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating stat...viewwe will contact you within 24 hours.
DSPPA Torch Relay in IndonesiaAugust 14, 2018DSPPA Torch Relay in Indonesia 18th Asian Games is going to be held on 18th August in Jakarta. Torch relay of the Asian Games will cover 54 cities with a total distance of 18000 km. As the official su...view
DSPPA | Donation of Cultural Relics to Heyuan City MuseumMay 16, 2022On the morning of May 12th, the donation of cultural relics from Wang Heng & Feng Jie and the opening ceremony of "Immortal Cultural Relics - Exhibition of Exquisite Cultural Relics Donated by Wang Heng & Feng Jie" was held in the Heyuan City Museum.view