EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating status and recording of operating logs. It meets the relevant standard of “EN54-16 Voice Alarm Control and Indicating Equipment”. The broadcasting system can be used for fire emergency broadcasting, daily service broadcasting and background broadcasting; this system is positioned as a small emergency broadcasting system, mainly used in small shopping malls, small office buildings and exhibition halls, etc.
PAVA9500E is an 8-zone expansion amplifier with main/backup switching function in the EN54-16 system, and is designed to be 2U high, with 2 microphone inputs, 4 analog inputs and 1 line output; provides optional amplifier module; supports the total power of up to 500W; holds 8 zone outputs, with the total power of 500W for all zones.


Model | PAVA9500 | PAVA9500E | ||
Rated Output Power | ≥500W (100V) | |||
Input Sensitivity | EMC MIC | 20mV 600Ω | —— | |
MIC | 5±0.5mV 10kΩ | |||
LINE | 1000±100mV 10kΩ | |||
Harmonic Distortion | EMC MIC | <1% 1kHz | —— | |
MIC | 1%1khz | |||
LINE | <1% 1kHz | |||
Frequency Response | EMC MIC | 80Hz-15kHz (±3dB) | —— | |
MIC | 1%1khz | |||
LINE | 50Hz-18kHz (±3dB) | |||
S/N Ratio | EMC MIC | >75dB (A-Weighted) | —— | |
MIC | 1%1khz | |||
LINE | >80dB (A-Weighted) | |||
EMC Line Auxiliary Output | Output Voltage | 1000mV | 1000mV | |
Frequency Range | 80Hz-15kHz (±3dB) | 80Hz-15kHz (±3dB) | ||
Harmonic Distortion | <1% 1kHz | <1% 1kHz | ||
System Connection Control Contact Output/Input | System Fault Relay Output | Short circuit, no voltage | ||
Emergency Mode Relay Output | Short circuit, no voltage | |||
Fire Reset Input | Short circuit, t≥0.5S, no voltage | |||
8-Channel Dry Contact Output | Short circuit, no voltage | |||
8-Channel Dry Contact Input | Short Circuit Mode | Short circuit input, no voltage | ||
Level Mode | 3.3V~24V | |||
Voice Message | Data Format | WAV | —— | |
Storage Type | SD card | —— | ||
Retention Time | >10 years | —— | ||
Working Power | AC | AC220V-240V/50-60Hz | ||
DC | DC 24V/17A | |||
Package Dimensions (L*W*H) | 625×635×165mm | |||
Machine Dimensions (L*W*H) | 483*430*88mm | |||
Gross Weight | 14kg | 13.3kg | ||
Net Weight | 12.05kg | 11.75kg | ||
PAVA9002 Fire Alarm Audio Notification System Network Control TerminalJune 27, 2023EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating stat...view
PAVA9008 16 Zones Remote Paging MicrophoneJune 27, 2023EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating stat...view
PAVA9008E Expansion Keyboard for Remote Paging MicrophoneJune 27, 2023EN54-16 fire emergency broadcasting system provides manual operation and timing programming, and gives priority to the former over the latter; supports real-time monitoring of equipment operating stat...viewwe will contact you within 24 hours.
System Components of City Smart PolesAugust 13, 2024Smart pole systems can utilize their extended sensing and communication equipment to collect various structured and unstructured data. This data is uploaded to a cloud-based public data system via pub...view
Attention Should Be Paid to the Design of Multimedia Conference SystemApril 25, 2022In the process of designing the multimedia conference system, we have undergone rigorous screening for the conception of the scheme, the design of the system, and the selection of equipment, and have ...view